Skip to content
Product
Double Duty® 4 is a low profile pump that offers you the versatility of combining a pump within a steam trap to aide in condensate drainage from a heat exchanger under all operating conditions. Features Non-Electric Low profile for tight space requirements Ductile iron body
Product
Armstrong Thermostatic Steam Traps are available with balanced-pressure bellows or wafer-type elements and are constructed in a variety of materials, including stainless steel, carbon steel and bronze. These traps are used on applications with very light condensate loads. THERMOSTATIC OPERATION Thermostatic steam traps operate on steam’s temperature difference from cooled...
Product
Armstrong offers a complete range of TC Series traps to handle the special requirements of clean steam systems. Different body configurations are available for choice of piping and ease of cleaning. The TC Series traps are constructed from 316L stainless steel for corrosion resistance and are highly polished for cleanability....
Product
Armstrong’s SH-1600 Series Bimetallic Steam Traps operate in superheat conditions, by the effect that rising temperature has on the bimetallic elements. How it Operates: At start-up the valve is wide open allowing a large volume of non-condensables and cold condensate to be removed from the system When the trap reaches...
Product
CD-33 Series is a disc-style trap designed to control the trap’s cycle rate. By reducing the cycle rate, the Armstrong CD-33 Series extends its service life well beyond that of typical disc traps. This enhanced performance minimizes maintenance time and greatly reduces steam costs. The CD-33 Series is designed with...
Product
Armstrong offers thermostatic air vents for positive venting of air and other non-condensable gases from steam in chamber-type heat-transfer equipment. Typical applications include jacketed kettles, retorts, vulcanizers, jacketed sterilizers or other contained equipment where air could accumulate in remote areas of the steam chamber and reduce heat-transfer capacity. These vents...
Product
800 Series Inverted Bucket Steam Trap in cast iron for horizontal installation, with continuous air venting at steam temperature, free-floating stainless steel mechanism, and discharge orifice at the top of the trap. The most reliable steam trap known—the inverted bucket—provides efficient condensate drainage of virtually all types of steam-using equipment....
Product
880 Series Inverted Bucket Steam Trap in cast iron for horizontal installation with integral strainer, continuous air venting at steam temperature, free-floating stainless steel mechanism, and discharge orifice at the top of the trap. The most reliable steam trap known—the inverted bucket—provides efficient condensate drainage of virtually all types of...
Product
Steam QM®-3 is an intelligent solution that allows pharmaceutical manufacturers, hospitals, and other healthcare facilities concerned with steam quality to easily and efficiently measure the quality of steam used for sterile applications. Steam QM®-3 is an automatic steam quality monitor that determines and communicates steam moisture content, the amount of...
Product
200 Series Inverted Bucket Steam Trap in cast iron for vertical installation, with continuous air venting at steam temperature, free floating stainless steel mechanism, and discharge orifice at the top of the trap. The most reliable steam trap known-the inverted bucket-provides efficient condensate drainage of virtually all types of steam-using...
Product
600F Series Inverted Bucket Traps, ductile iron construction with integral flange, continuous venting at steam temperature, free floating stainless steel mechanism, drain hole on top of the trap. The most reliable steam trap known—the inverted bucket—provides efficient condensate drainage of virtually all types of steam-using equipment. Put the inverted bucket...
Product
CS Series steam-to-steam humidifiers use existing boiler steam to produce clean steam from untreated water. Because these humidifiers use steam from a central boiler as a heat source, the humidifying steam can be produced more economically than from electricity. CS Series humidifiers consist of a heat exchanger submersed in a...
Product
Models 401-SH and 501-SH in carbon steel or stainless steel for vertical installation are made for overcoming the difficult combination of superheat and high pressure/low load service. To survive this most severe steam service, Armstrong created an inverted bucket trap with a unique accumulation chamber. The chamber collects sufficient condensate to...
Product
SH-900 Series Superheat Steam Traps operate by the effect that rising temperature has on the thermostatic bimetallic elements. At start-up, the valve is wide open, which allows a large volume of non-condensables and cold condensate to be removed from the system. When the system reaches steam temperature, the elements become...
Product
The effect of rising temperature on bimetallic elements operates the SH-2500 bimetallic steam trap. It adjusts to changing conditions because the curving of the bimetallic elements, caused by increasing temperature, compensates for increasing pressure. At start-up, the valve is wide open, which allows a large volume of non-condensables and cold...
Product
Armstrong B and BI Series Float & Thermostatic steam traps combine high standards of performance and long life with economy. They are ideal for heating service where continuous drainage with high air-venting capacity is required. Due to the wide use of vacuum returns in systems of this type, the thermostatic...
Product
Armstrong Intelligent Monitoring – AIM® 5700 – is a wireless monitoring technology that efficiently monitors and evaluates steam trap operation. The AIM® 5700 identifies the conditions of a steam trap to determine significant problems that could put your operation at risk. The AIM® 5700 can accurately detect potential issues such...
Product
Armstrong offers two thermostatic wafer steam traps in the WT Series: The WT-1 is ideal for low-capacity steam tracers and feature an exclusive non-welded wafer design, a sealed stainless steel body and an internal strainer screen two to three times larger than that of other thermostatic traps. Choose from NPT...
Product
1000 Series Inverted Bucket Steam Traps in stainless steel typically last three to four times longer than conventional traps used in identical services. Heat-treated stainless steel valves and seats are of the same design, material and workmanship as those used in traps for pressures up to 900 psig and 62...
Product
SH-300 Series Bimetallic Steam Traps for superheat or low load conditions are the ideal traps for applications where other trap styles are not suitable for long life. The Armstrong SH-300 Series bimetallic traps also have the ability to handle the large start-up loads associated with superheat applications. The unique bimetallic...
Product
AB-3000 Series Bimetallic Steam Traps operate by the effect that rising temperature has on bimetallic elements. It adjusts itself to changing conditions, as the increasing pressure on the valve is compensated by the curving of the bimetallic elements caused by the increasing temperature. Armstrong’s AB-3000 Series has a removable cap,...
Product
Until now measuring steam dryness fraction has largely been a manual process, which is time consuming and presents inherent safety and accuracy risks. Steam QM®-1 is an automatic steam quality monitor that continuously determines and communicates the dryness fraction of steam for more efficient management of a steam network. Steam...
Product
Armstrong ICS Series Float & Thermostatic steam traps are for industrial service from 0 to 465 psig (32 bar). The simple yet rugged construction of the ICS series carbon steel float and thermostatic trap is designed to assure long, trouble-free service. The ICS Float and Thermostatic steam trap is used...
Product
Model AB-3500 Bimetallic Steam Trap operates by the effect that rising temperature has on bimetallic elements. It adjusts itself to changing conditions, as the increasing pressure on the valve is compensated by the curving of the bimetallic elements caused by the increasing temperature. The Model AB-3500 has a removable cap,...